Nano Spectrophotometer LNS-202
Labocon Nano Spectrophotometer LNS 200 series is the next generation low volume spectrophotometers which have the ability to detect sample as low as 0.4ng/µl in the wavelength range of 195-835nm.
These systems possess the unique feature as there is no pre dilution require for any type of sample analysis and it can analyse the nucleic acid at the maximum concentration up to 15000ng.
Minimum Sample Size | 0.3-2.0 µl |
Wavelength Range | 200 – 850 nm |
Wavelength Accuracy | ±1 nm |
Wavelength Reproducibility | <±0.2 nm |
Absorbance Range | 0.002-300 |
Absorbance Accuracy | 1% (0.75 Abs at 350nm) |
Absorbance Precision | 0.002 Abs |
Spectral Resolution | 2 nm (FWHM at Hg 546) |
Path Length | 0.04 mm, 0.1 mm, 0.2 mm, 1 mm, 2 mm |
Light Source | Xenon flash lamp |
Life Time of Lamp | 109 flashes upto 10 years |
Detector | 2048-element linear silicon CCD |
Detection Range | Nucleic Acid up to 2-10000 ng/µl (dsDNA); BSA:0.08 mg/ml to 543 mg/ml |
Start-up Time | < 5s |
Measurement Time | < 5s |
Overall Dimension | 210x170x110 mm |
Power | 30 W |
Power Supply | 90-250V 50/60Hz |
Weight | 1.35 kg |
Catalog No. | 9241139164 |
The LNS-200 series Nano spectrophotometers are efficient enough to read the sample quantity from 0.3µl to 2.0 µl in less than 5sec.; which is suitable for various type of measurement such as:
• Peptides (205nm)
• DNA and RNA (260nm)
• Purified protein (280nm)
• Toxicology assays and industrial dyes (490nm)
• Gold nanoparticles (520nm)
• Colorimetric protein assays
• BCA( 562nm)
• Bradford (595nm)
• Modified Lowry (650nm)
• Optical Density measurements (600 nm)
• Wavelength range
- 200nm-850nm
• Wavelength accuracy
- ±1.0nm
• Easy user interface
- By pipetting, just drop the sample onto the sample point for direct measurement without any prior dilution.
• Low sample volumes
- Reduce sample loss and eliminate the need for dilution by using low volumes of samples in 0.3µl to 2.0µl for sample measurement. The appropriate path length can be selected automatically or by manual selection.
• Fast measurements
- Read-time is typically takes less than 5sec per sample without washing cuvettes or dilutes the samples
• Convenience and ease of use
- Calibration curves, kinetics or ratio measurements are all displayed at the touch of a button at connected computer.
• Reliability and robust instrumentation
- Press-to-read feature reduces the amount of time .Optics with no moving parts minimizes the incidence of optical misalignmentr
• Equipped with a built-in printer