Wavelength Range 190-900 nm
Wavelength Accuracy ±0.25 nm
Wavelength Repeatability 0.05 nm
Spectral Bandwidth 0.2, 0.4, 1.0, 2.0 nm
Temperature Range 10-35°C
Working Humidity ≤80%
Resolution <20%
Baseline Stability 0.002A/30min
Characteristic Concentration Limit Cu: 0.025g/ml/1%
Detection Limit Cu: 0.006g/ml
Background Calibration -
Overall Dimension 1000x400x470 mm
Weight 70 kg
Power 150 W
Power Supply 220V 50Hz
Catalog No. 9523128164

Labocon Atomic Absorption Spectrophotometer LAAS 100 series is widely used in analytical chemistry protocols, applications such as food and drug safety, clinical diagnostics, petrochemical, agricultural, environmental monitoring.

• Gas Control

  1. Software controlled quick gas conversion and safetyprotection device used to analyse airacetylene flame and nitrous oxide-acetylene flame

• Spray Chamber Metal Glass Spray

  1. Burner Corrosion resistant titanium burners available for both air/acetylene and nitrous-oxide acetylene

• Safety System

  1. Safety interlock mechanism that monitors the burner type, burner fitted, gas pressures. Flame on/off sensors; Power failure automatic shutdown. Liquid trap system, pressure relief plug and flame shield to protect from UV radiation

• Czerny-Turner grating monochromator

• Grating density of 1800 lines

• Anti-corrosive plastic sprayed chamber

• Metal glass spray set

• Photomultiplier tube as detector

• Optimized 3D lights for maximum energy

• Can distinguish between manganese light

• 0-10mA and 400Hz four lamps and optional six lamps with auto switch

• Air cooled pre-mixed 100mm single slit titanium burner

• Less than 1% precision

• Air-acetylene and oxygen enriched air-acetylene flame method

• Hydride generation spectrometry

• Automatic calibration, curve fitting and concentration calculation

• Automatic calculation of average concentration, standard deviation, relative standard deviation

• Acetylene gas leakage alarm

• Rapid and convenient test results opened in office software

• Software remote control to solve technical problems

• Windows XP/Vista operating system

• Equipped with graphite furnace

• RS232 software

• Graphite tubes

• Graphite furnace system

• Hydride generator

• Nitrous oxide generator

• Nitrous oxide regulator

• Acetylene regulator

• Recirculating cooling water system

• Printer