Atomic Absorption Spectrophotometer LAAS-101
Labocon Atomic Absorption Spectrophotometer LAAS-100 Series spectrophotometer, which offer superior base line stability of 0.002A/30min with advance optical system to ensure simple and reliable solution for trace elemental analysis.
Wavelength Range | 190-900 nm |
Wavelength Accuracy | ≤±0.5 nm |
Wavelength Repeatability | ≤0.3 nm (single direction) |
Spectral Bandwidth | 0.2, 0.4, 0.7, 1.4, 2.4, 5.0 nm |
Temperature Range | None |
Working Humidity | None |
Resolution | <40% |
Baseline Stability | ≤0.004Abs/30min |
Characteristic Concentration Limit | Cu: ≤0.04g/ml/1% |
Detection Limit | Cu: 0.008g/ml |
Background Calibration | Greater than 30 times |
Overall Dimension | 1220x770x730 mm |
Weight | 160 kg |
Power | 660 W |
Power Supply | 220V 50Hz |
Catalog No. | 9523126164 |
Labocon Atomic Absorption Spectrophotometer LAAS 100 series is widely used in analytical chemistry protocols, applications such as food and drug safety, clinical diagnostics, petrochemical, agricultural, environmental monitoring.
• Gas Control
- Software controlled quick gas conversion and safetyprotection device used to analyse airacetylene flame and nitrous oxide-acetylene flame
• Spray Chamber Metal Glass Spray
- Burner Corrosion resistant titanium burners available for both air/acetylene and nitrous-oxide acetylene
• Safety System
- Safety interlock mechanism that monitors the burner type, burner fitted, gas pressures. Flame on/off sensors; Power failure automatic shutdown. Liquid trap system, pressure relief plug and flame shield to protect from UV radiation
• Double beam
• Automatic compensation of light source and wavelength drift caused by temperature variation and electronic circuit drift
• Eliminates the need for pre-heating of cathode lamp to analyse the sample quickly
• Gas path system equipped with precision pressure and current stabilizing devices to obtain stable flame at low noise
• A very fine light beam passes through flame providing a precise analytical test with low characteristic concentration
• Adopts total reflection system to eliminate color difference
• Multi-functional analysis mode for flame absorption, flame emission, graphite furnace atomic absorption and hydride generation
• Quick gas conversion and safety protection device used to analyse air-acetylene flame and nitrous oxide-acetylene flame
• RS232 software
• Graphite tubes
• Graphite furnace system
• Hydride generator
• Nitrous oxide generator
• Nitrous oxide regulator
• Acetylene regulator
• Recirculating cooling water system
• Printer